Objective(s): 5-3.102002 NFPA 1001 Standard |
Primary Task: INTERIOR FIRE ATTACK, DIRECT APPLICATION |
||||||
|
Skill No. LIVE FIRE 1 - 1.1 |
Station No. LIVE FIRE - 1 |
Candidate No. |
|||||
|
INSTRUCTIONS TO THE MONITOR/EVALUATOR
1. The candidate shall be provided with three (3) charged hoselines with nozzle: 1", 1-1/2 or 1-3/4" and 2-1/2" 2. The candidate shall be provided with a structure suitable for live fire control and communication (radio) with outside personnel. 3. The candidate shall be provided with a team member/partner and a safety/back-up team (2 in - 2 out). 4. The candidate shall be informed as to where the fire is located within the structure. 5. The candidate shall be given the instructions below before beginning the task.
|
|||||||
|
INSTRUCTIONS TO THE CANDIDATE
1. “The candidate shall select the proper hoseline and shall demonstrate procedures for advancing the hoseline to the fire and demonstrate a direct attack method of extinguishment for a typical room and contents fire.”
|
|||||||
CANDIDATE PERFORMANCE |
YES |
NO |
|||||
|
¨ 1. Dons full PPE including SCBA, and is breathing from the SCBA. |
|
|
|||||
|
¨ 2. Selects the proper hoseline and nozzle for the task. (1-1/2 or 1-3/4" or larger) |
|
|
|||||
|
3. Communicates with partner/team member. |
|
|
|||||
|
4. Coordinates with Incident Command and other teams on the fireground by radio or other acceptable method. (accountability) |
|
|
|||||
|
5. Determines point of entry (extinguishment from an unburned area). |
|
|
|||||
|
¨ 6. Bleeds air from the hose line. |
|
|
|||||
|
¨ 7. Adjusts stream pattern on the nozzle (straight or solid). |
|
|
|||||
|
8. Extinguishes any burning fascia, cornice, overhanging, etc. or any potential exposure threats. |
|
|
|||||
|
¨ 9. Stays out of the doorway and opens doorway slowly. |
|
|
|||||
|
¨10. Advances line to the fire area by crawling or duck walk approach. |
|
|
|||||
|
11. Applies water from close proximity using proper stream. |
|
|
|||||
|
¨12. Applies water to the base of the fire. |
|
|
|||||
|
13. Applies water in short bursts until fire “darkens down”. |
|
|
|||||
|
14. Notifies Command that fire is under control. |
|
|
|||||
|
Reference: IFSTA Essentials 4th Edition Chapter 14 |
|
|
|||||
|
¨Critical Step - Failure on this step mandates failure on the entire objective! |
Total steps candidate must complete to Pass: |
10 |
TOTALS |
|
|
||
|
Test Date______________________________ Location:_____________________________________________ Candidate______________________________________________________SSN_________________________ Evaluation Location__________________________________________________________________________ Evaluator Signature______________________________________________ Date________________________ |
|||||||
TENNESSEE COMMISSION FIREFIGHTER I
ON FIREFIGHTING COMPETENCY EVALUATION
|
Objective(s): 5-3.10 2002 NFPA 1001 Standard |
Primary Task: INTERIOR FIRE ATTACK, COMBINATION APPLICATION |
||||||
|
Skill No. LIVE FIRE 1 - 1.2 |
Station No. LIVE FIRE - 1 |
Candidate No. |
|||||
|
INSTRUCTIONS TO THE MONITOR/EVALUATOR
1. The candidate shall be provided with three (3) charged hoselines with nozzle: 1", 1-1/2 or 1-3/4", and 2-1/2" 2. The candidate shall be provided with a structure suitable for live fire control and communication (radio) with outside personnel. 3. The candidate shall be provided with a team member/partner and a safety/back-up team (2 in - 2 out). 4. The candidate shall be informed as to where the fire is located within the structure. 5. The candidate shall be given the instructions below before beginning the task.
|
|||||||
|
INSTRUCTIONS TO THE CANDIDATE
1. “The candidate shall select the proper hoseline and shall demonstrate procedures for advancing the hoseline to the fire and demonstrate a combination attack method of extinguishment for a typical room and contents fire.”
|
|||||||
CANDIDATE PERFORMANCE |
YES |
NO |
|||||
|
¨ 1. Dons full PPE including SCBA, and is breathing from the SCBA. |
|
|
|||||
|
¨ 2. Selects the proper hoseline and nozzle for the task. (1-1/2 or 1-3/4") |
|
|
|||||
|
3. Communicates with partner/team member. |
|
|
|||||
|
4. Coordinates with Incident Command and other teams on the fireground by radio or other acceptable method. (accountability) |
|
|
|||||
|
5. Determines point of entry (extinguishment from an unburned area). |
|
|
|||||
|
¨ 6. Bleeds air from the hose line. |
|
|
|||||
|
¨ 7. Adjusts stream pattern on the nozzle (straight, solid or penetrating fog). |
|
|
|||||
|
8. Extinguishes any burning fascia, cornice, overhanging, etc. (may verbalize) |
|
|
|||||
|
¨ 9. Stays out of the doorway and opens doorway slowly. (may verbalize) |
|
|
|||||
|
¨10. Advances line to the fire area by crawling or duck walk approach. |
|
|
|||||
|
11. Applies water from a distance (once fire is seen) using proper stream. |
|
|
|||||
|
¨12. Applies water to the gases at the ceiling, then drops to base of fire (T or Z pattern). |
|
|
|||||
|
13. Applies water until fire “darkens down”. |
|
|
|||||
|
14. Notifies Command that fire is under control. |
|
|
|||||
|
Reference: IFSTA Essentials 4th Edition Chapter 14 |
|
|
|||||
|
¨Critical Step - Failure on this step mandates failure on the entire objective! |
Total steps candidate must complete to Pass: |
10 |
TOTALS |
|
|
||
|
Test Date______________________________ Location:_____________________________________________ Candidate______________________________________________________SSN_________________________ Evaluation Location__________________________________________________________________________ Evaluator Signature______________________________________________ Date________________________ |
|||||||
TENNESSEE COMMISSION FIREFIGHTER I
ON FIREFIGHTING COMPETENCY EVALUATION
|
Objective(s): 5-3.16 2002 NFPA 1001 Standard |
Primary Task: SELECT AND USE FIRE EXTINGUISHER |
||||||
|
Skill No. LIVE FIRE 1 - 1.3 |
Station No. LIVE FIRE - 1 |
Candidate No. |
|||||
|
INSTRUCTIONS TO THE MONITOR/EVALUATOR
1. Candidate shall be supplied with a minimum of three (3) different types of rated, hand held portable extinguishers. 2. The candidate shall be given the instructions below before beginning the exercise.
|
|||||||
|
INSTRUCTIONS TO THE CANDIDATE
1. “The candidate, given a group of three (3) different extinguishers, shall select and demonstrate the use of one (1) extinguisher on a fire.”
|
|||||||
|
CANDIDATE PERFORMANCE |
YES |
NO |
|||||
|
¨ 1. Selects the proper rated extinguisher for the fuel class involved (A,B or C). |
|
|
|||||
|
2. Stands the proper distance from the target (Closer than normal if using CO2). |
|
|
|||||
|
3. Pulls the handle retaining/safety pin. |
|
|
|||||
|
4. Aims the nozzle to the base of the flames. |
|
|
|||||
|
5. Squeezes the handle to release the extinguishing agent. |
|
|
|||||
|
6. Sweeps the fire of the burning material. |
|
|
|||||
|
Reference: IFSTA Essentials 4th Edition, Chapter 5 |
|
|
|||||
|
¨Critical Step - Failure on this step mandates failure on the entire objective! |
Total steps candidate must complete to Pass: |
5 |
TOTALS |
|
|
||
|
Test Date______________________________ Location:_____________________________________________ Candidate______________________________________________________SSN_________________________ Evaluation Location__________________________________________________________________________ Evaluator Signature______________________________________________ Date________________________ |
|||||||
TENNESSEE COMMISSION FIREFIGHTER I
ON FIREFIGHTING COMPETENCY EVALUATION
|
Objective(s): 5-3.8 2002 NFPA 1001 Standard |
Primary Task: ESTINGUISHING A DUMPSTER/TRASH FIRE |
||||||
|
Skill No. LIVE FIRE 1 - 1.4 |
Station No. LIVE FIRE - 1 |
Candidate No. |
|||||
|
INSTRUCTIONS TO THE MONITOR/EVALUATOR
1. The candidates shall be provided with the following: full set of structural personal protective equipment (PPE) and SCBA as assigned or issued by the authority having jurisdiction. 2. The candidates shall be provided with a 1 ¾” handline and a trash hook or similar tool. 3. The candidates shall operate as a team for this exercise. 4. The candidates shall be given the following instructions before beginning the exercise.
|
|||||||
|
INSTRUCTIONS TO THE CANDIDATE
“The candidates, provided with a handline and a trash hook, shall demonstrate how to extinguish a dumpster/trash fire.”
|
|||||||
|
CANDIDATE PERFORMANCE |
YES |
NO |
|||||
|
¨ 1. Don all appropriate PPE, including SCBA. |
|
|
|||||
|
2. Are aware of the hazards of their surroundings (i.e., traffic conditions). |
|
|
|||||
|
3. Approach the fire from the upwind/uphill side. |
|
|
|||||
|
4. Attack the fire as they approach from a safe distance. |
|
|
|||||
|
5. Utilize the trash hook to “stir” the material as they apply water. |
|
|
|||||
|
Reference: IFSTA Essentials 4th Edition Chapter 14 |
|
|
|||||
|
¨Critical Step - Failure on this step mandates failure on the entire objective! |
Total steps candidate must complete to Pass: |
4 |
TOTALS |
|
|
||
|
Test Date______________________________ Location:_____________________________________________ Candidate______________________________________________________SSN_________________________ Evaluation Location__________________________________________________________________________ Evaluator Signature______________________________________________ Date________________________ |
|||||||
TENNESSEE COMMISSION FIREFIGHTER I
ON FIREFIGHTING COMPETENCY EVALUATION
|
Objective(s): 5-3.7 2002 NFPA 1001 Standard |
Primary Task: EXTINGUISH A VEHICLE FIRE |
||||||
|
Skill No. LIVE FIRE 1 - 1.5 |
Station No. LIVE FIRE - 1 |
Candidate No. |
|||||
|
INSTRUCTIONS TO THE MONITOR/EVALUATOR
1. The candidate shall be provided with three (3) charged hoselines with adj. Fog nozzle: 1", 1-1/2 or 1-3/4" and 2-1/2". 2. The candidate shall be provided with a vehicle or simulated vehicle. 3. The candidate shall be provided with a team member/partner and a safety/back-up team. 4. The candidate shall be informed as to where the fire is located on the vehicle. 5. The candidate shall be given the instructions below before beginning the task.
|
|||||||
|
INSTRUCTIONS TO THE CANDIDATE 1. “The candidate shall select the proper hoseline and shall demonstrate procedures for extinguishing the vehicle fire indicated.” |
|||||||
|
CANDIDATE PERFORMANCE |
YES |
NO |
|||||
|
¨ 1. Dons full PPE including SCBA, and is breathing from the SCBA. |
|
|
|||||
|
2. Identify auto fuel type(s). |
|
|
|||||
|
3. Assess and control fuel leaks. |
|
|
|||||
|
¨ 4. Selects the proper hoseline and nozzle for the task. (not less than 1-1/2") |
|
|
|||||
|
5. Communicates with partner/team member. |
|
|
|||||
|
6. Bleeds air from the hose line. |
|
|
|||||
|
7. Adjusts stream pattern on the nozzle (straight or narrow fog pattern). |
|
|
|||||
|
8. Approach vehicle from upwind side, if possible. |
|
|
|||||
|
9. Approach vehicle from uphill side, if possible. |
|
|
|||||
|
10. Open all automobile compartments to expose hidden fires. |
|
|
|||||
|
11. Advances to a distance that allows reach by the fire stream. |
|
|
|||||
|
12. Extinguishes as much fire as possible from the maximum effective distance. |
|
|
|||||
|
13. Applies water in a straight stream to narrow fog pattern. |
|
|
|||||
|
14. Extinguishes any ground fire around the vehicle first. |
|
|
|||||
|
15. Applies stream directly to the burning material and hazard areas. |
|
|
|||||
|
16. Shuts down stream when fire extinguished. |
|
|
|||||
|
17. Performs overhaul. |
|
|
|||||
Reference: IFSTA Essentials 4th Edition Chapter 14
|
|
|
|||||
|
¨Critical Step - Failure on this step mandates failure on the entire objective! |
Total steps candidate must complete to Pass: |
12 |
TOTALS |
|
|
||
|
Test Date______________________________ Location:_____________________________________________ Candidate______________________________________________________SSN_________________________ Evaluation Location__________________________________________________________________________ Evaluator Signature______________________________________________ Date________________________ |
|||||||
TENNESSEE COMMISSION FIREFIGHTER I
ON FIREFIGHTING COMPETENCY EVALUATION
|
Objective(s): 5-3.19 2002 NFPA 1001 Standards |